Brain Tuner
This page was last updated on Date: 2008/12/08 15:00
See Sota Instruments
Brain Tuner web-page for an example of a commercially available brain tuner.
I have not tried to make or use a device of this type, so I cannot personally
comment as to the effectiveness/safety of this device. One user of this
device had the following to say to me:
The brain synchronizer distresses, relaxes but also clears the mind. People
also use it to break addictions and depression. It's really incredible.
I use mine everyday and it keeps me out of the chronic depression I used
to suffer.
I have been told to mention the following:
Builders
of this device should be aware that if they make and sell CES units to
others in the USA that they will be in legal jeopardy because the other
official CES companies will turn them in to the FDA. Currently one must
be FDA approved as a CES manufacturer in the USA in order to be within
the limits of the law.
Both myself and Dr. Beck agreed that it is important to reduce any DC to zero
or negligible amounts. Why? As noted DC creates a polarization effect which
drives ions to one electrode or the other.
This is the same effect as electroplating or electrolysis. In the body it is
known as electrophoresis (sp.?). The Bio-Tuner has an AC coupling transformer
on its output which prevents DC from passing through 100%. On the Silver
Pulser (blood cleaner) the output is a bi-phasic AC output. The polarity
switches every 1/4 second. The lower the frequency the higher chance of
DC polarization. However, Dr. Beck's research showed the 4 Hz output did
not cause any significant polarization as there was not enough time for
a build-up of ions to occur before the polarity switched over. I would say that 1-2 seconds on one
polarity would be about the maximum I would suggest. Now, Dr. Hulda Clark's
Zapper has a pulsed DC output. I can see that with
would cause some electrophoresis, but the small amount that it would cause
is offset by the positive benefits of the Zapper. Dr. Clark found that
a negative pulsed DC output was detrimental to her protocol.
Hope this helps!
Russ :>)
Here's a schematic for one to build yourself. As always, Experiment at your own risk. All other disclaimers apply here.
Brain Tuner Schematic
Parts List:
| Qty |
Mouser |
# |
Cost |
| 1 |
Project Box |
400-1542 |
3.70 |
| 1 |
9v rechargeable battery |
573-15F8K |
7.99 |
| 1 |
9v battery clip |
12BC160 |
.54 |
| 1 |
output transformer |
42TM006 |
2.41 |
| 1 |
C555 timer IC |
511-TS555CN |
.46 |
| 1 |
C556 timer IC |
511-TS556CN |
.62 |
| 1 |
8 pin IC socket |
571-26404633 |
.11 |
| 1 |
14 pin IC socket |
571-26403573 |
.13 |
| 1 |
100K pot |
31VA501 |
1.25 |
| 1 |
pot knob |
450-2070 |
.99 |
| 1 |
25K mini pot |
569-72PM-25K |
.99 |
| 2 |
3.5mm female jack |
16PJ137 |
.52 |
| 2 |
3.5mm male plug |
17PP103 |
.86 |
| 1 |
12v 200ma Adaptor |
412-1101 |
4.90 |
| 1 |
470uf capacitor |
140-XRL10V470 |
.18 |
| 1 |
1uf capacitor |
540-1.0M35 |
.33 |
| 1 |
.22uf capacitor |
540-0.22M35 |
.33 |
| 1 |
.0047uf capacitor |
581-UEC472J1 |
.62 |
| 1 |
130K 1/4w resistor |
30B-J250-130K |
.22 |
| 1 |
120K resistor |
30B-J250-120K |
.22 |
| 1 |
33K resistor |
30B-J250-33K |
.22 |
| 2 |
22K resistor |
30B-J250-22K |
.44 |
| 2 |
4.7K resistor |
30B-J250-4.7K |
.44 |
| 1 |
680 ohm resistor 1/2W |
30B-J500-680 |
.22 |
| 1.5" |
1/16" shrink tubing |
5174-11162 |
4'/.78 |
| |
|
|
|
| Qty |
Radio Shack |
# |
Cost |
| 2 |
2ma LED |
276-044 |
2.12 |
| 1 |
PC Board |
276-150 |
.64 |
| 3.5' |
24ga speaker wire |
278-1301 |
.27 |
| |
|
|
|
| Qty |
JDR |
# |
Cost |
| 1 |
SPDT switch |
SP/DT |
1.25 |
| 1 |
SPDT-CO switch |
SW22 |
1.29 |
| 1 |
1.5M resistor |
R1.5M |
.05 |
| 1 |
18K resistor |
R18K |
.05 |
| 2 |
10K resistor |
R10K |
.10 |
| 2 |
2.2K resistor |
R2.2K |
.10 |
| 1 |
50K mini pot |
72PR50K |
.79 |
| 1 |
10K mini pot |
72PR10K |
.79 |
| 1 |
1K mini pot |
72PR1.0K |
.79 |
| 2 |
2907 transistor |
2N2907A |
.29 |
| 2 |
3904 transistor |
2N3904 |
.10 |
| 4 |
1N4148 diode |
1N4148 |
.04 |
| 1 |
1N4001 diode |
1N4001 |
.06 |
| 4 |
Rubber Feet |
3M5012-BL |
100'/6.95 |
| 3.5' |
24ga single wire |
WIRE-24YSR100 |
100'/3.95 |
| |
|
|
|
| QTY |
Beads N Beyond |
# |
Cost |
| 2 |
Ear Clips** |
125 |
.25 |
** Sew 100% cotton cloth on Ear Clips. Wet with saltwater before using
Mouser Electronics: 1-800-346-6873 958 N Main St Mansfield TX 76063-4827 |
JDR Microdevices: 1-800-538-5000 1850 South 10th St San Jose, CA 95112-9941 |
Beads N Beyond: 1-704-254-7927 35 Wall St Asheville NC 28801
|
Excerpted from: FOCUS on ALCOHOL and DRUG ISSUES, Jan/Feb 1983
Cranial Electrotherapy Stimulation (CES)
Help for ANXIETY
Cranial Electrotherapy Stimulation has been used as a treatment for anxiety in
several parts of the world for over a quarter of a century. American medicine
has only recently begun to realize its use as a safe and effective treatment.
Studies show that CES treatment yields highly significant reductions in
anxiety, whether the patients were in a psychiatric setting, a scholastic
setting, an outpatient setting, or an in-patient general hospital setting.
Further, while many different kinds of anxiety have been studied, as measured
by the six different psychological measuring instruments found in these
studies, they all responded significantly to CES treatment. Less intense
or less permanent forms of anxiety - the so-called "situational anxiety"
in which a person habitually responds to personally threatening events
in his environment with an anxiety reaction - respond to CES treatments
within a week or less. The more permanent forms of anxiety - the so-called
trait anxiety, or that underlying level of anxiety that a person typically
carries with him at all times - require a longer period of CES treatment.
This kind of anxiety typically is not reduced significantly in fewer than
2 or 3 weeks of daily treatments.
Help for DEPRESSION
Studies show that reactive depression (that which results from acute changes in
the patients life situation such as a job change or divorce) is decreased
after 6 days of CES treatment.
More deep seated depression (endogenous) in some cases required 3 or more weeks
of daily treatment. For this reason, many physicians routinely prescribe
a minimum of 2 weeks to a month of daily CES treatments in depressed patients,
since it is frequently difficult to gauge the type or depth of depression
with great accuracy. Since many patients have a "depression habit" physicians
should include a home CES unit in their treatment plan so that the patient
can meet any new sign of impending depression with effective treatment
and thereby break the behavioral reinforcement chain that has both led
to and maintained the habit. In this way, a maladaptive habit can be effectively
controlled or broken without the use of frequent medications and/or repeated
visits to the physician. Other research has shown that CES, when used this
way is neither habit forming nor addictive. Such patients use it only when
they experience an impending medical necessity.
Help for INSOMNIA
Because CES was originally called "Electrosleep" in European countries, many earlier
American studies were designed to learn whether or not such small amounts
of electric currents would actually put people to sleep. That is, just
as 50ma of current - called "electro-anesthesia" - put an individual into
anesthesia so that surgical procedures could be performed, 1ma of CES current
was assumed to put them into a normal state of sleep if "Electrosleep"
worked. Such studies discovered that while CES does not necessarily "put
a person to sleep", it does accomplish some very therapeutic changes in
the sleep patterns of people who complain of insomnia.
The studies below show that whether measured by the patient's own ratings,
psychiatrists ratings or by electroencephalograph or polygraph recordings
before and after CES treatments, the following effects of CES in insomnia
can be expected:
- Sleep onset latency is reduced. That is, once a person has retired for the evening,
the amount of time it takes him to actually fall asleep is reduced from
one to two hours or more to the more normal twenty minutes or less.
- The number of awakenings during the night are reduced. That is, while most
insomniacs awaken three or more times during the night and have difficulty
falling asleep again, those treated with CES typically awaken no more than
once or twice following therapy, with most reporting no awakenings. Furthermore,
after awakening, they return to sleep much more promptly than before.
- CES treated patients spend more time in stage four sleep following CES treatments.
That is, patients spend more time in the deepest, most restful stage of
sleep than they did prior to CES treatment. It should be noted that some
patients who have deprived themselves of REM sleep - the stage during which
dreaming occurs - by taking drugs or alcohol as a sleeping aid, sometimes
spend the first two or three nights in unusually vivid dream states when
first starting CES treatments. This is considered another indication of
the therapeutic effectiveness of CES in that persons are known to become
increasingly disorganized mentally, some even to the point of psychotic-like
symptoms, when they do not engage in the normal amount of dreaming.
- Finally, it was discovered that many patients receiving CES treatments report feeling
more rested when they awaken in the morning following CES treatments.
Treatment parameters: While some patients begin to respond after the second or third
day of treatment, others do not have their best response with fewer than
24 days of treatments lasting from 15 minutes to 1 hour. The beneficial
effects have been measured in some experimental groups for as long as two
years. Some people with insomnia have a habitual pattern of responding
to situational stress with an interruption in their sleep patterns. The
best results are obtained when CES is used each time unusual stressors
occur in their life situations that would ordinarily cause poor sleep.
The CES device user is thereby trained over time to expect a good night's
sleep no matter what stressful interruptions occurred in the normal flow
of daily life.
Help for ADDICTIONS
Foremost among the treatment problems among chemically dependent persons is the
need to help them through the psychologically and physically demanding
period of withdrawal. The body reacts to the depressed physical state engendered
by alcohol and other drugs with a rebound stress reaction. This reaction
commonly includes states of extreme anxiety, depression, and insomnia,
for which CES treatment is known to be effective.
Underlying the addictive state is an insidious and progressive destruction of normal
brain functioning including an often incapacitating memory loss, inability
to process information involving abstract symbols, and other dysfunctions
associated with the organic brain syndrome, and advanced condition which
is known as Korsakoff psychosis. Studies on the use of CES in chemical
dependencies are among the best controlled and well designed research in
the U.S. They indicate that CES is a highly effective adjunct to methadone
withdrawal in heroin addicts, significantly shortening the time to symptom-free
withdrawal when compared with methadone alone, and significantly lowering
withdrawal anxiety as measured by the Taylor Manifest Anxiety Scale.
Further, the anxiety and depression accompanying and following withdrawal of both
alcohol and other drugs in polydrug abusers is significantly reduced when
patients receive CES as a post withdrawal treatment.
Most importantly, perhaps, is the finding that CES treatment halts and significantly
reverses brain dysfunction in these patients as measured on seven different
psychological scales of cognitive function, bringing many such functions
back to the level of the pre-addiction state in the majority of patients
studied. Another problem in the treatment of chemically dependent persons
is frequently recurring "dry withdrawal" in which the individual suffers
withdrawal symptoms within several weeks, then again in several months.
The phrases used to describe these phenomena are a "dry drunk" followed
by the "dry withdrawal".
These psychological states lead to high recidivism rates among these individuals
as they return to treatment after "falling off the wagon". CES is now thought
of as one of the most effective, non-drug treatments for these periods
of withdrawal, and a patient who has a personal CES unit available should
be able to use it to prevent a full-blown withdrawal reaction at such times.
By doing so he can reduce the need for additional medical treatment in
a clinic or hospital setting, and will be less likely to resort to alcohol
because of the discomfort accompanying these withdrawal states.
Brain Tuner Instructions
Frequency of Usage
For severe problems use it 40 minutes twice daily. For less than severe problems
use it 30-40 minutes once daily, then after a month you can use it 2 or
3 times a week. (It has cumulative effects.) More than 40 minutes usage
in one sitting can have less productive results.
Selecting 6 hz Option
6 hz (cycles per second) enhances Theta brain waves which are normally experienced
between sleep and full alertness. If you are stressed, anxious, hyper,
or are preparing for bed then flip the switch upwards towards the 6 hz
sticker. If you just woke up or want to be more alert then flip the switch
down away from the 6 hz sticker.
Using Ear Clip Electrodes
Pull open both ear clips and wet thoroughly with saltwater. Wipe your ear lobes
clean because dirt or oil can cause stinging sensations when using unit.
Clip them onto your ear lobes before turning the unit on. The saltwater
usually dries out after 45 minutes (and stops conducting electric current)
which is good because then you don't have to watch the clock too closely.
Turn unit off before handling electrodes to prevent electrical tingling
of your fingers.
Setting Current Control Knob
Before turning unit on, turn the dial fully counterclockwise. Turn unit on, wait
for any initial tingling to subside, and then slowly turn the dial clockwise
until you get uncomfortable tingling and then turn it back counterclockwise
into the comfort zone. The farther clockwise it is turned, the more electric
current you're receiving (and the more the current LED will light up).
Too much current can result in dizziness. When you first start using it
you may have uncomfortable sensations even with it turned fully counterclockwise.
This usually subsides quickly and then you can turn it up. If it don't
subside then you can adjust the electronics to suit you by turning the
unit off, removing the 4 bottom screws, pulling out the electronics board,
and with a mini-screwdriver turn the center of the potentiometer marked
"<-adjust" counterclockwise (while the unit is on and connected to you)
until you are comfortable with the diminished sensation felt. This is a
last resort though because too little current may result in less benefits.
Using AC Adapter
This unit is powered by an internal rechargeable battery that will need recharging
when you can't feel any tingling with the control fully clockwise. To recharge
the battery just turn the unit off and plug the AC adapter into the AC
wall socket and into the power jack on the unit. It will automatically
recharge like that. Let it recharge overnight or 14 hours for a maximum
charge. Too much charging may shorten the batteries life span. Next morning
it is ready to use for at least another 4 hours total. Don't connect the
AC adapter to the unit except when recharging. If the unit ever gets to
where it won't last long between charges then you can replace the internal
9v battery with Radio Shack's 9 volt rechargeable #23-299. Recharge after
replacing battery.
Caring for Electrodes
Handle electrodes carefully so as not to bend the wires where they connect to
the electrodes. If this connection ever breaks then you can remove the
cloth and solder the wire back in place. If cloth gets too dirty then you
can replace it by removing it, cutting a piece of 100% cloth the same size,
and re-stitching it back in place.
Making Saltwater
Mix 3 tsp non-iodized sea salt or rock salt with 2 ounce distilled water. Stir
and let sit for 3 hours. Store in a dark eyedropper bottle. Stir 1 drop
of this salt solution into 4 oz distilled water and use to fill an eyedropper
bottle for use on the electrodes.
|